new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Aug 18

HealthiVert-GAN: A Novel Framework of Pseudo-Healthy Vertebral Image Synthesis for Interpretable Compression Fracture Grading

Osteoporotic vertebral compression fractures (VCFs) are prevalent in the elderly population, typically assessed on computed tomography (CT) scans by evaluating vertebral height loss. This assessment helps determine the fracture's impact on spinal stability and the need for surgical intervention. However, clinical data indicate that many VCFs exhibit irregular compression, complicating accurate diagnosis. While deep learning methods have shown promise in aiding VCFs screening, they often lack interpretability and sufficient sensitivity, limiting their clinical applicability. To address these challenges, we introduce a novel vertebra synthesis-height loss quantification-VCFs grading framework. Our proposed model, HealthiVert-GAN, utilizes a coarse-to-fine synthesis network designed to generate pseudo-healthy vertebral images that simulate the pre-fracture state of fractured vertebrae. This model integrates three auxiliary modules that leverage the morphology and height information of adjacent healthy vertebrae to ensure anatomical consistency. Additionally, we introduce the Relative Height Loss of Vertebrae (RHLV) as a quantification metric, which divides each vertebra into three sections to measure height loss between pre-fracture and post-fracture states, followed by fracture severity classification using a Support Vector Machine (SVM). Our approach achieves state-of-the-art classification performance on both the Verse2019 dataset and our private dataset, and it provides cross-sectional distribution maps of vertebral height loss. This practical tool enhances diagnostic sensitivity in clinical settings and assisting in surgical decision-making. Our code is available: https://github.com/zhibaishouheilab/HealthiVert-GAN.

  • 6 authors
·
Mar 7, 2025

Varifocal-Net: A Chromosome Classification Approach using Deep Convolutional Networks

Chromosome classification is critical for karyotyping in abnormality diagnosis. To expedite the diagnosis, we present a novel method named Varifocal-Net for simultaneous classification of chromosome's type and polarity using deep convolutional networks. The approach consists of one global-scale network (G-Net) and one local-scale network (L-Net). It follows three stages. The first stage is to learn both global and local features. We extract global features and detect finer local regions via the G-Net. By proposing a varifocal mechanism, we zoom into local parts and extract local features via the L-Net. Residual learning and multi-task learning strategies are utilized to promote high-level feature extraction. The detection of discriminative local parts is fulfilled by a localization subnet of the G-Net, whose training process involves both supervised and weakly-supervised learning. The second stage is to build two multi-layer perceptron classifiers that exploit features of both two scales to boost classification performance. The third stage is to introduce a dispatch strategy of assigning each chromosome to a type within each patient case, by utilizing the domain knowledge of karyotyping. Evaluation results from 1909 karyotyping cases showed that the proposed Varifocal-Net achieved the highest accuracy per patient case (%) 99.2 for both type and polarity tasks. It outperformed state-of-the-art methods, demonstrating the effectiveness of our varifocal mechanism, multi-scale feature ensemble, and dispatch strategy. The proposed method has been applied to assist practical karyotype diagnosis.

  • 9 authors
·
Oct 13, 2018

Ventor-QTest: Threat-Model-Driven Verification of Vendor-Hosted LLM APIs

As large language models become increasingly widespread, third-party providers that deploy open-weight models have become an important part of the ecosystem. Auditing the quality of their inference APIs is therefore an open problem. We formalize hosted model routing as a stochastic process and propose \textbf{Ventor-QTest}, a composite black-box audit that requires no probability information from the target API. Its repeated-request component sends each frozen constrained context to the target multiple times, reconstructs a categorical output distribution from the returned text counts, and reports average fidelity loss (AFL) as a null-bias-corrected, within-window mean coarsened-KL statistic. Its long-sequence component uses independent runs to report extreme fidelity loss (EFL) through the empirical upper tail of a run-level reference-centered-surprisal statistic. Across three logprob-capable route conditions, AFL shows strong linear descriptive agreement with a logprob-derived coarsened-KL comparator. Across seven route snapshots, 20-run sequence probes reveal route-specific EFL variation. AFL and EFL have little detectable route-level association with GPQA-Diamond accuracy. In contrast, pronounced EFL coincides with a decline in Terminal-Bench pass rate as task exposure increases. This pattern may arise because correctness in long-horizon tasks is more sensitive to extreme fidelity loss. These results motivate reporting AFL and EFL jointly, particularly when auditing long-horizon agentic tasks. The open-source implementation is available at https://github.com/Tencent/AI-Infra-Guard/tree/main/services/api_checker/ventor_qtest.

tencent Tencent
·
Aug 16 1

Progressive Supernet Training for Efficient Visual Autoregressive Modeling

Visual Auto-Regressive (VAR) models significantly reduce inference steps through the "next-scale" prediction paradigm. However, progressive multi-scale generation incurs substantial memory overhead due to cumulative KV caching, limiting practical deployment. We observe a scale-depth asymmetric dependency in VAR: early scales exhibit extreme sensitivity to network depth, while later scales remain robust to depth reduction. Inspired by this, we propose VARiant: by equidistant sampling, we select multiple subnets ranging from 16 to 2 layers from the original 30-layer VAR-d30 network. Early scales are processed by the full network, while later scales utilize subnet. Subnet and the full network share weights, enabling flexible depth adjustment within a single model. However, weight sharing between subnet and the entire network can lead to optimization conflicts. To address this, we propose a progressive training strategy that breaks through the Pareto frontier of generation quality for both subnets and the full network under fixed-ratio training, achieving joint optimality. Experiments on ImageNet demonstrate that, compared to the pretrained VAR-d30 (FID 1.95), VARiant-d16 and VARiant-d8 achieve nearly equivalent quality (FID 2.05/2.12) while reducing memory consumption by 40-65%. VARiant-d2 achieves 3.5 times speedup and 80% memory reduction at moderate quality cost (FID 2.97). In terms of deployment, VARiant's single-model architecture supports zero-cost runtime depth switching and provides flexible deployment options from high quality to extreme efficiency, catering to diverse application scenarios.

  • 8 authors
·
Nov 20, 2025

Autonomous labeling of surgical resection margins using a foundation model

Assessing resection margins is central to pathological specimen evaluation and has profound implications for patient outcomes. Current practice employs physical inking, which is applied variably, and cautery artifacts can obscure the true margin on histological sections. We present a virtual inking network (VIN) that autonomously localizes the surgical cut surface on whole-slide images, reducing reliance on inks and standardizing margin-focused review. VIN uses a frozen foundation model as the feature extractor and a compact two-layer multilayer perceptron trained for patch-level classification of cautery-consistent features. The dataset comprised 120 hematoxylin and eosin (H&E) stained slides from 12 human tonsil tissue blocks, resulting in ~2 TB of uncompressed raw image data, where a board-certified pathologist provided boundary annotations. In blind testing with 20 slides from previously unseen blocks, VIN produced coherent margin overlays that qualitatively aligned with expert annotations across serial sections. Quantitatively, region-level accuracy was ~73.3% across the test set, with errors largely confined to limited areas that did not disrupt continuity of the whole-slide margin map. These results indicate that VIN captures cautery-related histomorphology and can provide a reproducible, ink-free margin delineation suitable for integration into routine digital pathology workflows and for downstream measurement of margin distances.

  • 12 authors
·
Nov 27, 2025

Loud or Silent? A Reusable Framework for Per-Modality Failure Analysis in Multimodal Clinical AI

Multimodal clinical models are usually judged on accuracy with every modality present, but deployment removes modalities; an echocardiogram is often unavailable where an ECG is routine. Two questions then matter beyond the size of the accuracy loss: which modality was responsible, and whether the model fails loudly or silently once that modality is dropped. The distinction is per-example and modality-level, and is separate from post-hoc feature attribution (e.g. SHAP). Models are replaced often; the evaluation that answers these questions is reused. We present a model-agnostic modality-failure framework: given N modality embeddings, any mask-aware probe, and labels, it returns a per-example failure taxonomy, a per-modality complementarity matrix that attributes error to modalities, and a loud-vs-silent dropout profile separating monitorable failures from those that pass unflagged far from the decision boundary, using only deployment-observable signals. We release it as a small, unit-tested harness and validate it against planted ground truth. Across seeds it recovers that planted modality dominance and complementary subset, reports per-modality loud-vs-silent rates, and scales to a three-modality complementarity matrix; because the planted structure is known by construction, this validates recovery of per-example attribution rather than clinical performance. We then instantiate the framework on frozen EchoJEPA and HuBERT-ECG embeddings for LVEF and the EF <= 40% HFrEF gate over a paired MIMIC-IV cohort, where on the held-out test split (n = 245) dropping echo nearly doubles error. The narrow echo-to-ECG overlap that bounds cohort size is itself a deployment finding for cardiac foundation models. All of our work can be found at https://github.com/criticaldata/PRIMED-AI.

Single Image BRDF Parameter Estimation with a Conditional Adversarial Network

Creating plausible surfaces is an essential component in achieving a high degree of realism in rendering. To relieve artists, who create these surfaces in a time-consuming, manual process, automated retrieval of the spatially-varying Bidirectional Reflectance Distribution Function (SVBRDF) from a single mobile phone image is desirable. By leveraging a deep neural network, this casual capturing method can be achieved. The trained network can estimate per pixel normal, base color, metallic and roughness parameters from the Disney BRDF. The input image is taken with a mobile phone lit by the camera flash. The network is trained to compensate for environment lighting and thus learned to reduce artifacts introduced by other light sources. These losses contain a multi-scale discriminator with an additional perceptual loss, a rendering loss using a differentiable renderer, and a parameter loss. Besides the local precision, this loss formulation generates material texture maps which are globally more consistent. The network is set up as a generator network trained in an adversarial fashion to ensure that only plausible maps are produced. The estimated parameters not only reproduce the material faithfully in rendering but capture the style of hand-authored materials due to the more global loss terms compared to previous works without requiring additional post-processing. Both the resolution and the quality is improved.

  • 2 authors
·
Oct 11, 2019

HMAR: Efficient Hierarchical Masked Auto-Regressive Image Generation

Visual Auto-Regressive modeling (VAR) has shown promise in bridging the speed and quality gap between autoregressive image models and diffusion models. VAR reformulates autoregressive modeling by decomposing an image into successive resolution scales. During inference, an image is generated by predicting all the tokens in the next (higher-resolution) scale, conditioned on all tokens in all previous (lower-resolution) scales. However, this formulation suffers from reduced image quality due to the parallel generation of all tokens in a resolution scale; has sequence lengths scaling superlinearly in image resolution; and requires retraining to change the sampling schedule. We introduce Hierarchical Masked Auto-Regressive modeling (HMAR), a new image generation algorithm that alleviates these issues using next-scale prediction and masked prediction to generate high-quality images with fast sampling. HMAR reformulates next-scale prediction as a Markovian process, wherein the prediction of each resolution scale is conditioned only on tokens in its immediate predecessor instead of the tokens in all predecessor resolutions. When predicting a resolution scale, HMAR uses a controllable multi-step masked generation procedure to generate a subset of the tokens in each step. On ImageNet 256x256 and 512x512 benchmarks, HMAR models match or outperform parameter-matched VAR, diffusion, and autoregressive baselines. We develop efficient IO-aware block-sparse attention kernels that allow HMAR to achieve faster training and inference times over VAR by over 2.5x and 1.75x respectively, as well as over 3x lower inference memory footprint. Finally, HMAR yields additional flexibility over VAR; its sampling schedule can be changed without further training, and it can be applied to image editing tasks in a zero-shot manner.

  • 9 authors
·
Jun 4, 2025

Tackling Data Heterogeneity in Federated Learning via Loss Decomposition

Federated Learning (FL) is a rising approach towards collaborative and privacy-preserving machine learning where large-scale medical datasets remain localized to each client. However, the issue of data heterogeneity among clients often compels local models to diverge, leading to suboptimal global models. To mitigate the impact of data heterogeneity on FL performance, we start with analyzing how FL training influence FL performance by decomposing the global loss into three terms: local loss, distribution shift loss and aggregation loss. Remarkably, our loss decomposition reveals that existing local training-based FL methods attempt to reduce the distribution shift loss, while the global aggregation-based FL methods propose better aggregation strategies to reduce the aggregation loss. Nevertheless, a comprehensive joint effort to minimize all three terms is currently limited in the literature, leading to subpar performance when dealing with data heterogeneity challenges. To fill this gap, we propose a novel FL method based on global loss decomposition, called FedLD, to jointly reduce these three loss terms. Our FedLD involves a margin control regularization in local training to reduce the distribution shift loss, and a principal gradient-based server aggregation strategy to reduce the aggregation loss. Notably, under different levels of data heterogeneity, our strategies achieve better and more robust performance on retinal and chest X-ray classification compared to other FL algorithms. Our code is available at https://github.com/Zeng-Shuang/FedLD.

  • 6 authors
·
Aug 22, 2024

MIRAGE: Multi-scale Lesion-Informed Representation with Auxiliary Guidance for MRI Contrast Enhancement

Inferring contrast enhancement from one pre-contrast breast MRI slice is underdetermined: post-contrast appearance contains physiological information that is not uniquely encoded in baseline anatomy. Optimizing only paired pixel fidelity can suppress uncertain lesion enhancement, whereas adversarial or stochastic generative objectives can favor realistic post-contrast appearance without guaranteeing patient-specific lesion fidelity. We introduce MIRAGE, a residual 2D U-Net that combines global reconstruction and perceptual losses with three forms of lesion-aware supervision available only during training: an asymmetric penalty for missed tumor enhancement, multi-scale auxiliary tumor segmentation, and guidance through a frozen post-contrast tumor segmentation nnU-Net. We evaluate the method on 301 cases from the multi-centre MAMA-SYNTH data using eight complementary image-, region-, radiomics-, and segmentation-based metrics. MIRAGE ranks first on six metrics and markedly improves downstream lesion localization over tuned pix2pix, conditional diffusion, and latent bridge-matching baselines. The generative alternatives retain advantages in LPIPS or contrast classification, revealing a clear fidelity-utility trade-off. Leave-one-in and leave-one-out ablations show that the losses are partly redundant for lesion localization but exert distinct effects on appearance, radiomics, and boundary accuracy. These results support task-aware synthesis while also showing that its apparent optimality is conditional on the downstream models and metrics used to define utility.

  • 4 authors
·
Jul 20

iTRIALSPACE: Programmable Virtual Lesion Trials for Controlled Evaluation of Lung CT Models

We introduce iTRIALSPACE, a programmable evaluation framework for controlled assessment of lung CT models. Standard benchmarks are static retrospective collections that entangle lesion size, lobe prevalence, anatomy, and acquisition context, making it difficult to determine what structurally drives model accuracy. iTRIALSPACE addresses this limitation by composing real clinical CTs and lesion profiles into controlled virtual lesion trials through a four-stage pipeline: multidataset nodule profiling, explicit trial specification, anatomy-aware mask insertion, and ControlNet-conditioned CT synthesis. The framework is built on a unified 54-attribute nodule-profile dataset spanning 13,140 annotated nodules from seven public CT sources and instantiated as 13 trial modes. We evaluate iTRIALSPACE in a 55,469-sample Virtual Lesion Study spanning three medical VLMs, four spatialguidance conditions, and three clinical tasks. Across all 13 modes, the synthetic substrate remains within the real-to-real FID baseline, and synthetic performance rankings transfer strongly to real clinical data (ρ = 0.93, p < 10^{-15}). Controlled trial modes expose findings unavailable to fixed-distribution benchmarks, including shortcut-driven size prediction collapse under lobe-equalized sampling and hostto-donor variance ratios of 8.9x and 3.3x in twin-cross analysis. These results position iTRIALSPACE as an auditable evaluation infrastructure for controlled, falsifiable testing beyond static retrospective benchmarks.

  • 4 authors
·
May 6

QualityFM: a Multimodal Physiological Signal Foundation Model with Self-Distillation for Signal Quality Challenges in Critically Ill Patients

Photoplethysmogram (PPG) and electrocardiogram (ECG) are commonly recorded in intesive care unit (ICU) and operating room (OR). However, the high incidence of poor, incomplete, and inconsistent signal quality, can lead to false alarms or diagnostic inaccuracies. The methods explored so far suffer from limited generalizability, reliance on extensive labeled data, and poor cross-task transferability. To overcome these challenges, we introduce QualityFM, a novel multimodal foundation model for these physiological signals, designed to acquire a general-purpose understanding of signal quality. Our model is pre-trained on an large-scale dataset comprising over 21 million 30-second waveforms and 179,757 hours of data. Our approach involves a dual-track architecture that processes paired physiological signals of differing quality, leveraging a self-distillation strategy where an encoder for high-quality signals is used to guide the training of an encoder for low-quality signals. To efficiently handle long sequential signals and capture essential local quasi-periodic patterns, we integrate a windowed sparse attention mechanism within our Transformer-based model. Furthermore, a composite loss function, which combines direct distillation loss on encoder outputs with indirect reconstruction loss based on power and phase spectra, ensures the preservation of frequency-domain characteristics of the signals. We pre-train three models with varying parameter counts (9.6 M to 319 M) and demonstrate their efficacy and practical value through transfer learning on three distinct clinical tasks: false alarm of ventricular tachycardia detection, the identification of atrial fibrillation and the estimation of arterial blood pressure (ABP) from PPG and ECG signals.

  • 3 authors
·
Sep 8, 2025