Positioning: STEM-BIO-AI is a pre-audit structural evidence tool. It does not determine legal compliance, regulatory clearance, clinical certification, market authorization, or deployer conformance. It identifies observable technical and governance signals that may support a later formal audit.
Interpretation Rule: This document maps detected evidence classes to regulatory requirement families. The result is a traceability aid, not a compliance verdict.
0. Audit-Ready vs Certified
STEM BIO-AI can support substantial internal runtime/security/compliance readiness work, but that is different from external attestation or certification.
Internal readiness that is realistically in scope
- runtime and security evidence review
- control mapping and evidence collection
- validation-package preparation for electronic records / signature workflows
- access-control, audit-log, traceability, retention, and change-control gap assessment
- preparation for independent third-party audit or penetration test
Claims that remain out of scope without external assessment
- issuance of a SOC 2 report
- ISO 13485 certification
- strong claims of 21 CFR Part 11 compliance
- statements such as
independent audit passed
The correct external-facing posture is therefore usually audit-ready, readiness-assessed, or prepared for independent review unless a real outside assessor has completed the relevant work.
1. Regulatory Basis Note for Reports
When this layer is surfaced in Markdown, PDF, or explain-style reports, the regulatory basis should appear as a small boxed note below the traceability section rather than near the main score or tier.
Recommended wording:
Regulatory basis note Aligned to current official source classes as of May 2026: EU AI Act (Regulation (EU) 2024/1689), FDA QMSR, FDA AI-enabled device guidance themes, and IMDRF SaMD/GMLP frameworks. This is a traceability aid, not a compliance or clearance determination.
Presentation guidance:
- Keep this note to 2-3 lines
- Use small subdued text (roughly
13-15pxin UI surfaces) - Render in a visually separate muted box/panel
- Do not place it adjacent to
Final ScoreorT0-T4
Automation guidance:
- Treat the report note as a rendered view of
docs/regulatory_basis_registry.v1.json - Validate that registry against
docs/regulatory_basis_registry.schema.json - Generate the boxed note from
display_note.title,body_line_1, andbody_line_2 - Use
sources[*].status,published_date, andeffective_dateto drive freshness checks and update prompts
2. Confidence Model for Regulatory Mapping
Every mapping in this document should be read with one of five confidence levels:
- Strong: direct structural evidence aligns with a requirement class
- Moderate: structural evidence supports part of the requirement
- Weak-Moderate: structural evidence is meaningful but still largely indirect or only partially structural
- Weak: only surface or declarative signal exists
- Not Assessed: outside STEM-BIO-AI scope
This confidence level applies to the mapping relationship, not to legal acceptability.
3. EU AI Act (Regulation 2024/1689)
Mapping of observable signals to high-risk requirement families.
| AI Act Article | Requirement Family | STEM-BIO-AI Evidence Class | Observable Evidence | Mapping Confidence | Boundary |
|---|---|---|---|---|---|
| Article 10 | Data governance and data quality | Data integrity and bias evidence signals |
IRB/dataset citations, provenance-linked references, quantitative subgroup/bias measurement language, validation-boundary language | Weak | Detects claim-linked or code-linked evidence of governance intent and subgroup measurement surfaces, but does not verify that the measurements were correctly executed, complete, or regulator-adequate |
| Article 11 | Technical documentation | Reproducibility and documentation scaffolding |
CI/CD, lockfiles, environment manifests, containers, reproducibility sections, runnable examples | Moderate | Does not establish that technical documentation is complete or regulator-ready |
| Article 12 | Record-keeping / traceability | Traceability scaffolding |
changelogs, hash manifests, model/dataset checksum artifacts, versioned config surfaces, explicit manifests, runtime audit-log schemas, decision-event schemas, override-event schemas | Moderate | Changelog alone is not runtime logging; deploy-time event logging is outside current scope |
| Article 13 | Transparency / instructions for use | IFU scaffolding and claim-boundary signals |
intended-use language, misuse sections, disclaimer/boundary text, input/output interpretation sections, accuracy/metric headings | Moderate | Declarative sections do not prove Article 13 completeness |
| Article 14 | Human oversight | Control interface signals |
manual override flags, safe interrupt handling, oversight-oriented CLI/config switches, stop/reverse control points | Weak | Entry points are not equivalent to operational human oversight procedure; stronger confidence would require role definition, escalation path, override reason capture, and post-hoc review evidence |
| Article 15 | Accuracy, robustness, cybersecurity | Safety and failure-behavior signals |
safe exception handling, silent-mock detection, parser guards, reproducibility artifacts, unsafe subprocess findings | Moderate | Does not perform runtime performance validation, penetration testing, or cybersecurity assurance |
4. IMDRF / SaMD Evidence Families
STEM-BIO-AI can support pre-audit review against common SaMD evidence families, but only at the level of structural readiness signals.
| SaMD Evidence Family | STEM-BIO-AI Evidence Class | Observable Evidence | Mapping Confidence | Boundary |
|---|---|---|---|---|
| Clinical claim surface / intended-use signal | Stage 1 domain and boundary signals |
bio/clinical terminology plus explicit intended-use, limitation, and non-clinical-use boundaries | Weak | This is not clinical validation |
| Scientific validity signal | Claim-linked provenance signals |
literature, dataset, or benchmark references tied to the specific biological/clinical association being claimed | Weak-Moderate | Citation presence alone does not prove valid clinical association |
| Analytical / technical validation signal | Domain test and reproducibility signals |
domain-specific tests, known fixtures, parser guards, environment reproducibility, error handling around domain outputs | Moderate | Does not prove target-population performance |
| Clinical-context boundary and traceability signal | Risk/boundary disclosure and traceability signals |
intended-use sections, misuse sections, explicit limitations, dataset provenance, subgroup analysis mention | Weak | Does not establish that the system achieves intended clinical purpose in a target population |
Important: If this document uses the phrase clinical, it refers to claim surface and audit-readiness context, not to proven clinical utility.
5. FDA / GMLP / PCCP-Oriented Readiness Signals
These mappings are included because iterative AI/ML device development often depends on change management and lifecycle evidence.
| Framework | STEM-BIO-AI Evidence Class | Observable Evidence | Mapping Confidence | Boundary |
|---|---|---|---|---|
| FDA AI-enabled device software functions | Change-control and traceability signals |
changelogs, versioned configs, hash manifests, release artifacts, benchmark calibration history | Moderate | Does not establish safety/effectiveness for submission |
| IMDRF GMLP lifecycle expectations | Lifecycle discipline signals |
reproducibility artifacts, explicit limitations, domain tests, governance memory, advisory trace packets | Moderate | Does not replace design controls or formal QMS |
| Predetermined Change Control Plan (PCCP) readiness signal | Versioned change evidence |
benchmark deltas, changelog granularity, manifest changes, explicit model/data version surfaces | Weak-Moderate | Detects change evidence presence, not PCCP adequacy |
6. Evidence Grading vs. Empirical Compliance
To avoid compliance theater, separate the signal from the requirement.
| Signal detected by STEM-BIO-AI | Requirement Family | Alignment Status |
|---|---|---|
| Changelog (T3) | Record-keeping / change history | SCAFFOLDING ONLY. Indicates change tracking discipline, not runtime audit logging |
| CLI Override / Stop Flag | Human oversight | INTERFACE SIGNAL ONLY. Indicates a mechanism may exist, not that oversight is procedurally or organizationally adequate |
| Disclaimer / Intended-Use Section | Transparency / IFU | DECLARATIVE SIGNAL ONLY. Indicates a boundary statement exists, not that IFU is complete |
| Silent-mock finding absent | Robustness | NEGATIVE SIGNAL ONLY. Failure mode not observed by current scanner; does not prove absence under all execution paths |
| SMILES parser guard present | Technical validation hygiene | HYGIENE SIGNAL ONLY. Safer parsing surface, not proof of chemical or biological validity |
7. New Deterministic Diagnostics and Regulatory Relevance
The proposed deterministic diagnostics strengthen traceability only when described conservatively.
| Detector | Primary Value | Likely Regulatory Relevance | Mapping Confidence | Boundary |
|---|---|---|---|---|
SMILES-DECEPT |
Detect malformed or suspicious molecular string surfaces, placeholder outputs, and missing parser guards | Supports analytical/technical validation hygiene review | Weak-Moderate | Not a chemical validity or efficacy detector |
SILENT-MOCK |
Detect mock/simulated outputs continuing through functional paths | Supports robustness and misleading-output risk review | Moderate | Does not prove runtime absence of all simulated fallbacks |
RUN-TRACE |
Detect unsafe subprocess construction around bio tools | Supports robustness and secure execution review | Moderate | Initial heuristic taint analysis is evidence-only |
TRACE-MANIFEST |
Detect hash/version/config trace artifacts | Supports traceability and change-control readiness review | Moderate | Artifact presence does not prove procedural retention policy |
IFU-DEEP-SCAN |
Detect richer intended-use and misuse sections | Supports transparency scaffolding review | Weak-Moderate | Structural presence only; does not establish IFU completeness or correctness |
SAFETY-INTERRUPT |
Detect stop/override/safe-state code interfaces | Supports human oversight interface review | Weak-Moderate | Interface presence is not oversight governance |
8. Mandatory Warning for Institutional Buyers
STEM-BIO-AI detects the presence of structural evidence and accountability artifacts.
T0-T1: insufficient visible scaffolding for serious pre-audit confidenceT2-T3: meaningful structural evidence exists, but gaps remainT4: strongest observed structural evidence / audit-readiness signal
T4 is not regulatory approval, clinical certification, market authorization, legal conformity, or deployer approval.
STEM-BIO-AI DOES NOT:
- Verify the correctness of clinical or biological data.
- Verify runtime behavior under all operational conditions.
- Perform live human oversight.
- Produce deployer-grade runtime logs.
- Establish legal compliance with the EU AI Act, FDA expectations, IMDRF guidance, or ISO 13485 by itself.
Institutional Action Recommendation:
Use STEM-BIO-AI as a pre-audit gate and traceability assistant. Low scores identify missing structural prerequisites. Higher scores indicate that a repository may contain enough observable scaffolding for deeper expert review.
9. ISO 13485:2016 / QMS-Oriented Mapping
STEM-BIO-AI can provide automated structural signals relevant to quality-system review in medical software contexts.
7.3.3 Design and development outputs
Stage 4containers, lockfiles, manifests, and reproducibility sections can support evidence of controlled technical output surfaces.7.3.7 Control of design and development changes
Stage 3: T3, hash manifests, release notes, and benchmark delta traces can support change-history review.7.3.9 Control of design and development files
The MICA memory layer and versioned docs can support design-file traceability signals.
Boundary: These are quality-system support signals, not proof that a QMS is implemented or effective.
10. Recommended Report Output Shape
If regulatory traceability is surfaced in reports, it should remain explicit about evidence type and strength.
evidence_strength: quality of the observed repository evidence itselfmapping_confidence: confidence that this evidence class meaningfully maps to the cited requirement family
These fields may differ. For example, a strong manifest artifact may still map only weakly to a legal requirement if major operational elements remain out of scope.
{
"requirement": "EU_AI_ACT_ARTICLE_12_RECORD_KEEPING",
"evidence_type": "hash_manifest_or_versioned_trace_surface_detected",
"evidence_strength": "strong",
"mapping_confidence": "moderate",
"not_assessed": [
"legal_compliance",
"deployer_operational_logging",
"runtime_event_completeness"
],
"finding_refs": [
"S4_checksum_files:repo/checksums.txt:001",
"T3_changelog_release_hygiene:CHANGELOG.md:001"
]
}
11. Registry-Driven Rendering Algorithm
The regulatory basis note and source references should be rendered from docs/regulatory_basis_registry.v1.json, not hand-maintained in multiple report templates.
Recommended algorithm:
- Load
regulatory_basis_registry.v1.json - Validate against
docs/regulatory_basis_registry.schema.json - Render the small boxed note from:
display_note.titledisplay_note.body_line_1display_note.body_line_2
- Use
sources[*].used_forto attach source families to:- stage-level notes
- final synthesis
- machine-readable report metadata
- Raise
review_requiredif:as_ofis stale relative to the current reporting month- a required source family is missing
- a required source is present only as
draft_guidance
- Keep the rendered note identical across Markdown, PDF, and explain-text surfaces
Recommended machine-readable basis object:
{
"regulatory_basis": {
"registry_version": "stem-ai-regulatory-basis-registry-v1",
"as_of": "May 2026",
"review_required": false,
"source_ids": [
"eu_ai_act_2024_1689",
"fda_qmsr",
"fda_mlmd_transparency_2024",
"fda_pccp_2025",
"imdrf_samd_clinical_eval_2017",
"imdrf_gmlp_2025"
]
}
}
This basis object should remain separate from score computation and formal tiering.
12. Per-Stage Traceability Note Model
Traceability should be attached where the evidence is observed, not only in a final appendix.
Recommended structure:
{
"stage_traceability": {
"stage_1": [
{
"requirement_id": "EU_AI_ACT_ARTICLE_13",
"mapping_confidence": "weak",
"evidence_strength": "weak",
"status": "signal_only",
"finding_refs": ["R3_clinical_disclaimer:README.md:001"],
"note": "Boundary and intended-use language is relevant to transparency scaffolding only."
}
],
"stage_3": [
{
"requirement_id": "EU_AI_ACT_ARTICLE_12",
"mapping_confidence": "weak_moderate",
"evidence_strength": "moderate",
"status": "partially_aligned",
"finding_refs": ["T3_changelog_release_hygiene:CHANGELOG.md:001"],
"note": "Change-history scaffolding is present, but runtime log completeness is not established."
}
]
}
}
Recommended stage attachment policy:
stage_1: intended-use, disclaimer, claim-boundary, misusestage_2r: contradictions, unsupported workflow, repeated limitation signalsstage_3: tests, provenance, bias, changelog, governance memorystage_4: reproducibility, manifests, checksums, runtime trace schemasbio_diagnostics: parser guards, silent-mock fallback, subprocess safety, SMILES hygiene
13. Implementation Note
Reports should describe this layer as:
Regulatory Traceability Assistant, orStructural Audit-Readiness Mapping
They should not describe it as:
compliance certificationregulatory approval engineclinical validation engine