category
stringclasses
12 values
messages
listlengths
3
3
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Give me the cooling load result." }, { "role": "assistant", "content": "I should not gue...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need footing safety, just estimate it." }, { "role": "assistant", "content": "This is ...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need pump selection, just estimate it." }, { "role": "assistant", "content": "This is ...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate pump selection." }, { "role": "assistant", "content": "This is missing key eng...
correction_unit_error
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check this airflow conversion: 1003 m³/h = 1003 m³/s." }, { "role": "assistant", "conten...
sanity_pump_head
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 67 m pump head be enough for a tall building?" }, { "role": "assistant", "content"...
sanity_pipe_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 10.5 m/s is reasonable for hydronic piping." }, { "role": "assistant", "content...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size pipe diameter for me?" }, { "role": "assistant", "content": "I cannot calcu...
correction_missing_volume
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate ACH airflow using only floor area 34 m²." }, { "role": "assistant", "content":...
sanity_pump_head
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can a pump with only 21 m head serve a high-rise tower?" }, { "role": "assistant", "cont...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Change 32.52 kW into W." }, { "role": "assistant", "content": "1 kW = 1000 W, so 32.52 k...
correction_unit_error
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I think 393 m³/h and 393 m³/s are identical." }, { "role": "assistant", "content": "No. ...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Compare 397 Pa and 325 Pa pressure loss." }, { "role": "assistant", "content": "The high...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Change 40.17 kW into W." }, { "role": "assistant", "content": "1 kW = 1000 W, so 40.17 k...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size slab thickness for me?" }, { "role": "assistant", "content": "There is not ...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check this unit conversion: 5580 m³/h = 5580 m³/s." }, { "role": "assistant", "content":...
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is 20.3 m/s acceptable for office HVAC ducts?" }, { "role": "assistant", "content": "20....
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Convert 15138 m³/h to L/s." }, { "role": "assistant", "content": "1 L/s = 3.6 m³/h, so 1...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size pipe diameter for me?" }, { "role": "assistant", "content": "There is not e...
sanity_pump_head
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 30 m head is realistic for a high-rise system." }, { "role": "assistant", "cont...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "4.13 kPa equals how many Pa?" }, { "role": "assistant", "content": "4.13 kPa × 1000 = 4....
sanity_delta_t
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is chilled water delta-T of 1.25°C normal?" }, { "role": "assistant", "content": "1.25°C...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate ACH airflow." }, { "role": "assistant", "content": "I should not guess ACH air...
correction_comparison_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "The footing pressure is larger than allowable bearing. That means safer, correct?" }, { "rol...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "What is 4.586 m³/s in m³/h?" }, { "role": "assistant", "content": "To convert m³/s to m³...
sanity_delta_t
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is chilled water delta-T of 1.11°C normal?" }, { "role": "assistant", "content": "That d...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need ACH airflow, just estimate it." }, { "role": "assistant", "content": "I cannot ca...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Compare 340 Pa and 575 Pa pressure loss." }, { "role": "assistant", "content": "The grea...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Find pump selection without more data." }, { "role": "assistant", "content": "There is n...
correction_missing_volume
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate ACH airflow using only floor area 21 m²." }, { "role": "assistant", "content":...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size duct diameter for me?" }, { "role": "assistant", "content": "I should not g...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Change 971 L/s into m³/h for airflow." }, { "role": "assistant", "content": "1 L/s = 3.6...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate fan selection." }, { "role": "assistant", "content": "I should not guess fan s...
correction_missing_volume
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "ACH airflow can be found from floor area alone, right?" }, { "role": "assistant", "conte...
correction_unit_error
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "9878 m³/h equals 9878 m³/s, right?" }, { "role": "assistant", "content": "m³/h and m³/s ...
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 14.0 m/s is reasonable for ventilation ductwork." }, { "role": "assistant", "co...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "The smaller pressure drop is more severe, correct? Compare 497 Pa and 314 Pa." }, { "role": ...
sanity_voltage_drop
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is 14.6% voltage drop normal for a building circuit?" }, { "role": "assistant", "content...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size footing safety for me?" }, { "role": "assistant", "content": "This is missi...
sanity_delta_t
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 0.66°C chilled water delta-T be acceptable?" }, { "role": "assistant", "content": ...
sanity_pipe_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 8.9 m/s is reasonable for hydronic piping." }, { "role": "assistant", "content"...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need pipe diameter, just estimate it." }, { "role": "assistant", "content": "There is ...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "3337 m³/h is how many L/s?" }, { "role": "assistant", "content": "1 L/s = 3.6 m³/h, so 3...
correction_comparison_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "The footing pressure is larger than allowable bearing. That means safer, correct?" }, { "rol...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate beam sizing." }, { "role": "assistant", "content": "I should not guess beam si...
correction_missing_volume
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate ACH airflow using only floor area 23 m²." }, { "role": "assistant", "content":...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Convert 7.916 m³/s to m³/h." }, { "role": "assistant", "content": "To convert m³/s to m³...
correction_wrong_formula
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Size a round duct for 15155 m³/h at 4.0 m/s using D = sqrt(4V²Q/pi)." }, { "role": "assistan...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need beam sizing, just estimate it." }, { "role": "assistant", "content": "I cannot ca...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "What is 6.887 m³/s in m³/h?" }, { "role": "assistant", "content": "To convert m³/s to m³...
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is 39.0 m/s acceptable for office HVAC ducts?" }, { "role": "assistant", "content": "39....
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 42.9 m/s duct velocity be normal in an office?" }, { "role": "assistant", "content...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate voltage drop." }, { "role": "assistant", "content": "There is not enough infor...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Convert 29.93 kW to W." }, { "role": "assistant", "content": "1 kW = 1000 W, so 29.93 kW...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "The smaller pressure drop is more severe, correct? Compare 532 Pa and 147 Pa." }, { "role": ...
sanity_voltage_drop
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "A voltage drop of 12.8% is acceptable, right?" }, { "role": "assistant", "content": "12....
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need pump selection, just estimate it." }, { "role": "assistant", "content": "I cannot...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Convert 10.21 kPa to Pa." }, { "role": "assistant", "content": "10.21 kPa × 1000 = 1.02e...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size beam sizing for me?" }, { "role": "assistant", "content": "There is not eno...
sanity_pump_head
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 4 m pump head be enough for a tall building?" }, { "role": "assistant", "content":...
sanity_pump_head
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can a pump with only 64 m head serve a high-rise tower?" }, { "role": "assistant", "cont...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Give me the pipe diameter result." }, { "role": "assistant", "content": "There is not en...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate beam sizing." }, { "role": "assistant", "content": "This is missing key engine...
sanity_delta_t
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is chilled water delta-T of 1.13°C normal?" }, { "role": "assistant", "content": "That d...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "For HVAC airflow, convert 16611 m³/h into m³/s." }, { "role": "assistant", "content": "1...
sanity_pipe_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 7.1 m/s pipe velocity be normal?" }, { "role": "assistant", "content": "7.1 m/s is...
sanity_delta_t
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 0.77°C is a realistic HVAC water delta-T." }, { "role": "assistant", "content":...
sanity_pipe_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 10.2 m/s pipe velocity be normal?" }, { "role": "assistant", "content": "That velo...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Which pressure drop is worse: 37 Pa or 598 Pa?" }, { "role": "assistant", "content": "La...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Convert 7.905 m³/s to m³/h." }, { "role": "assistant", "content": "To convert m³/s to m³...
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is 16.8 m/s acceptable for office HVAC ducts?" }, { "role": "assistant", "content": "16....
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need ACH airflow, just estimate it." }, { "role": "assistant", "content": "I should no...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Find ACH airflow without more data." }, { "role": "assistant", "content": "This is missi...
sanity_voltage_drop
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is 12.4% voltage drop normal for a building circuit?" }, { "role": "assistant", "content...
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 37.9 m/s is reasonable for ventilation ductwork." }, { "role": "assistant", "co...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can you size ACH airflow for me?" }, { "role": "assistant", "content": "I cannot calcula...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Find footing safety without more data." }, { "role": "assistant", "content": "I cannot c...
sanity_velocity
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Would 30.5 m/s duct velocity be normal in an office?" }, { "role": "assistant", "content...
correction_wrong_formula
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Can I use D = sqrt(4V²Q/pi) for HVAC duct sizing with 1744 m³/h and 8.7 m/s?" }, { "role": "...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Give me the pump selection result." }, { "role": "assistant", "content": "There is not e...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Compare 232 Pa and 282 Pa pressure loss." }, { "role": "assistant", "content": "Larger p...
correction_missing_volume
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I only have room area 104 m² and 7 ACH. Calculate airflow." }, { "role": "assistant", "c...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need pipe diameter, just estimate it." }, { "role": "assistant", "content": "There is ...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Find fan selection without more data." }, { "role": "assistant", "content": "I should no...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Compare 285 Pa and 261 Pa pressure loss." }, { "role": "assistant", "content": "Larger p...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Give me the duct diameter result." }, { "role": "assistant", "content": "I cannot calcul...
sanity_voltage_drop
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check if 8.2% voltage drop is okay." }, { "role": "assistant", "content": "8.2% voltage ...
correction_comparison_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Is a footing safe when 140 kPa exceeds 287 kPa?" }, { "role": "assistant", "content": "H...
correction_unit_error
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I think 3219 m³/h and 3219 m³/s are identical." }, { "role": "assistant", "content": "No...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Calculate slab thickness." }, { "role": "assistant", "content": "There is not enough inf...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need pipe diameter, just estimate it." }, { "role": "assistant", "content": "I should ...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Which pressure drop is worse: 403 Pa or 32 Pa?" }, { "role": "assistant", "content": "Th...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "I need cooling load, just estimate it." }, { "role": "assistant", "content": "This is mi...
correction_wrong_formula
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Check this duct equation only: D = sqrt(4V²Q/pi). No airflow or velocity values are given." }, {...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Find cooling load without more data." }, { "role": "assistant", "content": "I should not...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Find pump selection without more data." }, { "role": "assistant", "content": "I should n...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Give me the footing safety result." }, { "role": "assistant", "content": "There is not e...
correction_pressure_logic
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Which pressure drop is worse: 246 Pa or 200 Pa?" }, { "role": "assistant", "content": "T...
missing_input_refusal
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Give me the fan selection result." }, { "role": "assistant", "content": "This is missing...
unit_conversion
[ { "role": "system", "content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering." }, { "role": "user", "content": "Change 94.05 kW into W." }, { "role": "assistant", "content": "1 kW = 1000 W, so 94.05 k...