category stringclasses 12
values | messages listlengths 3 3 |
|---|---|
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can I use D = sqrt(4V²Q/pi) for HVAC duct sizing with 3074 m³/h and 8.4 m/s?"
},
{
"role": "... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 6.164 m³/s to m³/h."
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I only have room area 16 m² and 7 ACH. Calculate airflow."
},
{
"role": "assistant",
"co... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "For HVAC airflow, convert 14627 m³/h into m³/s."
},
{
"role": "assistant",
"content": "1... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find beam sizing without more data."
},
{
"role": "assistant",
"content": "I should not ... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 362 m³/h to L/s."
},
{
"role": "assistant",
"content": "1 L/s = 3.6 m³/h, so 362... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "What is 3.597 m³/s in m³/h?"
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can I use D = sqrt(4V²Q/pi) for HVAC duct sizing with 13687 m³/h and 3.4 m/s?"
},
{
"role": ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate pipe diameter."
},
{
"role": "assistant",
"content": "There is not enough info... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "A voltage drop of 18.4% is acceptable, right?"
},
{
"role": "assistant",
"content": "18.... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "18931 m³/h equals 18931 m³/s, right?"
},
{
"role": "assistant",
"content": "18931 m³/h i... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "192.33 kW equals how many watts?"
},
{
"role": "assistant",
"content": "1 kW = 1000 W, s... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 1742 L/s to m³/h."
},
{
"role": "assistant",
"content": "1 L/s = 3.6 m³/h, so 17... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 36.4 m/s is reasonable for ventilation ductwork."
},
{
"role": "assistant",
"co... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 39 m²."
},
{
"role": "assistant",
"content":... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The smaller pressure drop is more severe, correct? Compare 479 Pa and 377 Pa."
},
{
"role": ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need cooling load, just estimate it."
},
{
"role": "assistant",
"content": "I should n... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 4.8 m/s okay for chilled water piping?"
},
{
"role": "assistant",
"content": "4.8 m/s... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The smaller pressure drop is more severe, correct? Compare 393 Pa and 503 Pa."
},
{
"role": ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need duct diameter, just estimate it."
},
{
"role": "assistant",
"content": "I cannot ... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Compare 126 Pa and 142 Pa pressure loss."
},
{
"role": "assistant",
"content": "Larger p... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 0.49°C chilled water delta-T be acceptable?"
},
{
"role": "assistant",
"content": ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate slab thickness."
},
{
"role": "assistant",
"content": "I cannot calculate slab... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the fan selection result."
},
{
"role": "assistant",
"content": "I should not gu... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "ACH airflow can be found from floor area alone, right?"
},
{
"role": "assistant",
"conte... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need voltage drop, just estimate it."
},
{
"role": "assistant",
"content": "I cannot c... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I used D = sqrt(4V²Q/pi) for 9776 m³/h and 3.3 m/s. Correct?"
},
{
"role": "assistant",
... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 22.5% voltage drop is okay."
},
{
"role": "assistant",
"content": "That voltage... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is a footing safe when 255 kPa exceeds 155 kPa?"
},
{
"role": "assistant",
"content": "T... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "9116 m³/h equals 9116 m³/s, right?"
},
{
"role": "assistant",
"content": "That conversio... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is a footing safe when 382 kPa exceeds 144 kPa?"
},
{
"role": "assistant",
"content": "N... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 24.0 m/s acceptable for office HVAC ducts?"
},
{
"role": "assistant",
"content": "24.... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need fan selection, just estimate it."
},
{
"role": "assistant",
"content": "There is ... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The smaller pressure drop is more severe, correct? Compare 259 Pa and 288 Pa."
},
{
"role": ... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 91 m²."
},
{
"role": "assistant",
"content":... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 9.2 m/s okay for chilled water piping?"
},
{
"role": "assistant",
"content": "9.2 m/s... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 42.6 m/s duct velocity be normal in an office?"
},
{
"role": "assistant",
"content... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find voltage drop without more data."
},
{
"role": "assistant",
"content": "This is miss... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "A voltage drop of 12.3% is acceptable, right?"
},
{
"role": "assistant",
"content": "Tha... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is a footing safe when 321 kPa exceeds 118 kPa?"
},
{
"role": "assistant",
"content": "H... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can a pump with only 67 m head serve a high-rise tower?"
},
{
"role": "assistant",
"cont... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find cooling load without more data."
},
{
"role": "assistant",
"content": "There is not... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I used D = sqrt(4V²Q/pi) for 16786 m³/h and 5.2 m/s. Correct?"
},
{
"role": "assistant",
... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate cooling load."
},
{
"role": "assistant",
"content": "I should not guess coolin... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the voltage drop result."
},
{
"role": "assistant",
"content": "I should not gue... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 99 m²."
},
{
"role": "assistant",
"content":... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Which pressure drop is worse: 50 Pa or 102 Pa?"
},
{
"role": "assistant",
"content": "La... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need pipe diameter, just estimate it."
},
{
"role": "assistant",
"content": "This is m... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "13429 m³/h equals 13429 m³/s, right?"
},
{
"role": "assistant",
"content": "m³/h and m³/... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 33 m head is realistic for a high-rise system."
},
{
"role": "assistant",
"cont... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find duct diameter without more data."
},
{
"role": "assistant",
"content": "There is no... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 37.0 m/s acceptable for office HVAC ducts?"
},
{
"role": "assistant",
"content": "Tha... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size pipe diameter for me?"
},
{
"role": "assistant",
"content": "I should not g... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Which pressure drop is worse: 185 Pa or 42 Pa?"
},
{
"role": "assistant",
"content": "Th... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size duct diameter for me?"
},
{
"role": "assistant",
"content": "I cannot calcu... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the slab thickness result."
},
{
"role": "assistant",
"content": "There is not e... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 24.1 m/s is reasonable for ventilation ductwork."
},
{
"role": "assistant",
"co... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 113 m²."
},
{
"role": "assistant",
"content"... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The footing pressure is larger than allowable bearing. That means safer, correct?"
},
{
"rol... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "567 W equals how many kW?"
},
{
"role": "assistant",
"content": "1000 W = 1 kW, so 567 W... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 41.7 m/s is reasonable for ventilation ductwork."
},
{
"role": "assistant",
"co... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can I use D = sqrt(4V²Q/pi) for HVAC duct sizing with 4213 m³/h and 5.3 m/s?"
},
{
"role": "... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Size a round duct for 8656 m³/h at 3.3 m/s using D = sqrt(4V²Q/pi)."
},
{
"role": "assistant... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is chilled water delta-T of 0.94°C normal?"
},
{
"role": "assistant",
"content": "0.94°C... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is a footing safe when 349 kPa exceeds 167 kPa?"
},
{
"role": "assistant",
"content": "H... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is chilled water delta-T of 0.28°C normal?"
},
{
"role": "assistant",
"content": "0.28°C... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 22.5% voltage drop is okay."
},
{
"role": "assistant",
"content": "22.5% voltag... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need duct diameter, just estimate it."
},
{
"role": "assistant",
"content": "This is m... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 20.9% voltage drop is okay."
},
{
"role": "assistant",
"content": "20.9% voltag... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find cooling load without more data."
},
{
"role": "assistant",
"content": "This is miss... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "What is 6.445 m³/s in m³/h?"
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate fan selection."
},
{
"role": "assistant",
"content": "This is missing key engi... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 11.2 m/s is reasonable for hydronic piping."
},
{
"role": "assistant",
"content... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the ACH airflow result."
},
{
"role": "assistant",
"content": "I should not gues... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can a pump with only 26 m head serve a high-rise tower?"
},
{
"role": "assistant",
"cont... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the beam sizing result."
},
{
"role": "assistant",
"content": "There is not enou... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate duct diameter."
},
{
"role": "assistant",
"content": "This is missing key engi... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is chilled water delta-T of 0.39°C normal?"
},
{
"role": "assistant",
"content": "0.39°C... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I think 10563 m³/h and 10563 m³/s are identical."
},
{
"role": "assistant",
"content": "... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 84 m²."
},
{
"role": "assistant",
"content":... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 20.5 m/s acceptable for office HVAC ducts?"
},
{
"role": "assistant",
"content": "20.... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "236678 W equals how many kW?"
},
{
"role": "assistant",
"content": "1000 W = 1 kW, so 23... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow."
},
{
"role": "assistant",
"content": "There is not enough inform... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Change 12494 m³/h into L/s."
},
{
"role": "assistant",
"content": "1 L/s = 3.6 m³/h, so ... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 67 m²."
},
{
"role": "assistant",
"content":... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 1139 L/s to m³/h."
},
{
"role": "assistant",
"content": "1 L/s = 3.6 m³/h, so 11... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate slab thickness."
},
{
"role": "assistant",
"content": "I should not guess slab... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the slab thickness result."
},
{
"role": "assistant",
"content": "This is missin... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 5.3 m/s pipe velocity be normal?"
},
{
"role": "assistant",
"content": "The value ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need voltage drop, just estimate it."
},
{
"role": "assistant",
"content": "I should n... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find beam sizing without more data."
},
{
"role": "assistant",
"content": "This is missi... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 7.5 m/s okay for chilled water piping?"
},
{
"role": "assistant",
"content": "That ve... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 16.2 m/s duct velocity be normal in an office?"
},
{
"role": "assistant",
"content... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 7.3 m/s pipe velocity be normal?"
},
{
"role": "assistant",
"content": "The value ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the voltage drop result."
},
{
"role": "assistant",
"content": "I cannot calcula... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate voltage drop."
},
{
"role": "assistant",
"content": "This is missing key engin... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find pipe diameter without more data."
},
{
"role": "assistant",
"content": "This is mis... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 0.5°C chilled water delta-T be acceptable?"
},
{
"role": "assistant",
"content": "... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find voltage drop without more data."
},
{
"role": "assistant",
"content": "There is not... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find duct diameter without more data."
},
{
"role": "assistant",
"content": "I cannot ca... |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.